Performance

Energy

Thermal insulation - Uf
1.3 W/m²K
Thermal insulation - Uw
0.86 W/m²K
Uw Dependencies
Frame-vent: Ug 0.6W/m²K, psi: 0.032W/mK @1.23x1.48m (93mm sight line), 38mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E1200 (1200Pa)
Wind load resistance
Class C4 (1600Pa)
Acoustics - Rw(C;Ctr)
49(-1;-5) dB
Opening & closing resistance
Class 3 (20000 cycles)

Safety

Burglar resistance
RC2
Impact resistance
I4
Operating Forces Class
Class 1
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Max. height of vent
2800 mm
Min. width of vent
500 mm
Max. width of vent
1400 mm
Max. weight of vent
150 kg
Max. weight of glass
1200 kg

Sightlines

Min. frame width (inward opening)
80 mm
Min. vent width (inward opening)
0 mm
Min. frame-vent width (inward opening)
80 mm
Min. vent-vent width (inward opening)
127 mm
Min. width T-profile
107 mm
Depth frame
77 mm
Depth Vent
77 mm
Depth frame-vent
87 mm

Glazing

Rebate height
16.5 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead - Structural Glued Glazing
Min. glass thickness - frame/element
32 mm
Max. glass thickness - frame/element
62 mm
Min. glass thickness - vent
30 mm
Max. glass thickness - vent
65 mm